DSA1030(3GHz -138dBm),DSA1030-TG(3GHz -138dBm TG),
DSA1030A(3GHz -148dBm),DSA1030A-TG(3GHz -148dBm TG)
특 징
▶ 평균 잡음 레벨 (DANL) : -138dBm(DSA1030), -148dBm(DSA1030A)
▶ Phase Noise : -80dBc/Hz @10kHz offset(DSA1030), -88 dBc/Hz @10 kHz offset(DSA1030A)
▶ 최소분해능 (RBW) : 100Hz(DSA1030), 10Hz(DSA1030A)
▶ Tracking Generator (optional)
▶ 고급측정기능(AMK) 기본지원(DSA1030A Only)
▶ Preamplifier (optional)
▶ 8.5 Inch WVGA (800x480) LCD 디스플레이
화 면
가까이 있는 신호의 분리
피크테이블(표) 기능
Noise 마커를 활용한 Phase noise 측정
-80 dBc/Hz Phase Noise @10 kHz offset
Quasi-Peak & EMI Filter 지원(기본)
Powerful PC software Option
사 양
Model | DSA1030 | DSA1030A |
주파수 대역 | 9kHz to 3GHz |
평균 잡음 레벨(DANL) | Min. : -138 dBm | Min. : -148 dBm |
Phase Noise | Min. : -80 dBc/Hz @10 kHz offset | Min. : -88 dBc/Hz @10 kHz offset |
최소 분해능 | 100 Hz (RBW) | 10 Hz (RBW) |
Interface | USB Host& Device, LAN(LXI-C), AUX |
화면 크기 | 8.5 Inch WVGA LCD 디스플레이 |
Option | Preamplifier, AMK, TG, GPIB | Preamplifier, TG, GPIB |
표준부속품
▶ Front Panel Cover (FPCS-DSA1000)
▶ Quick Guide (Hard Copy)
▶ Power Cable Conforming to the Standard of the country
Options
▶ PA-DSA1000 : Pre Amplifier (for DSA1030 and DSA1030-TG)
▶ AMK-DS1000 : Advanced measurement kit (for DSA1030 and DSA1030-TG)
▶ EMI Test System : PC software for EMI Pre-Competible testing
▶ Ultra-spectrum : PC based software
▶ DSA Utility Kit, RF Adaptor Kit, RF CATV Kit, RF Attenuator Kit, ATT03301H, CB-NM-NM-75-L-12G, CB-NM-SMAM-75-L-12G
▶ TX1000 : RF demo kit (transmitter)
▶ RX1000 : RF demo kit (receiver)
▶ VB1032 : VSWR bridge, 1MHz to 3.2GHz
▶ VB1040 : VSWR bridge, 800MHz to 4GHz
▶ VB1080 : VSWR bridge, 2GHz to 8GHz
▶ NFP-3 : Near field probe
▶ RM-DSA1000 : Rack mount kit
▶ BAG-DSA1000 : Soft carrying bag
▶ USB-GPIB : USB to GPIB interface converter for instrument
▶ ARM : Desk Mount Instrument Arm
F A Q
How do I achieve the lowest DANL with my spectrum analyzer?
Attenuator = 0dB Preamplifier ON Center Frequency = 10MHz RBW = 10Hz Span = 10KHz
DSA-1000 Introduction This document contains instructions on operating a Rigol DSA for the first time.
TX1000 Application Note Here is an application note that covers using the TX1000 RF Demo Kit. Including software installation, Bandpass filter, RF Amplifier, and other controls.
What products are LXI compliant? The attached document lists the LXI Compliant instruments.
Using A Tracking Generator Ken Wyatt explains a tracking generator on his EMC blog. Leave Rigol to read it on the blog site.
Do I need to have the Advanced Measurement Kit to use UltraSpectrum?
No. You will only need a license for UltraSpectrum. There are available advanced measurements within UltraSpectrum. These measurements include ACP, TOI, and others. To retrieve these measurements, the instrument must have the advanced measurement kit (AMK part number)
Request the Latest Firmware Click here and input information and we will get back to you with information on new firmware features and options available.
S1210 EMI Software Data Sheet
Where do I find instrument drivers for LabVIEW?
When I plug in my instrument via USB, I get a Windows Page Fault error (Blue Screen of Death / BSoD). There is a known issue with the IVI VISA Shared components version. See attached document for more details.
DSA Ethernet connectivity troubleshooting Here are some hints and tips to successfully connecting and testing the Ethernet connection on the Rigol DSA line of instruments.
Software Compatibility The attached PDF file describes Windows 7 Compatibility Issues.
DSA Packing list Here is a sample of the packing list for the DSA family of spectrum analyzer's.
DSA Calibration Certificate Here is a sample of the calibration certificate for the DSA family of spectrum analyzers.
VISA Runtime for Apple OS X To use a VISA compatible Rigol instrument under Apple OS X, the user must install National Instruments VISA run-time engine for OS X As of this writing the latest OS X VISA run-time engine from National Instruments is NI-VISA 5.0 NI-VISA 5.0 can be downloaded directly
Working with DSA Correction factors Here are instructions on working with DSA correction factors.
Spectrum analyzer detector selection guide. Spectrum analyzers have many options when it comes to input detector configurations. This document provides a guide to selecting the proper filter for the input signal type.
DSA External Trigger Rate The DSA 1000, 1000A, and 800 series of spectrum analyzers have an external trigger rate of approximately 5Hz.
Help File Error: Navigation to web page cancelled. Some instrument manuals are compiled HTML files with extensions ending in .CHM. On occasion, they have shown "Navigation to web page cancelled". Here are some steps to help solve that error.
Using A Tracking Generator Ken Wyatt explains a tracking generator on his EMC blog. Leave Rigol to read it on the blog site.
VB1020/1030 VSWR Bridge User's Guide and Data Sheet. Here is the spec sheet for the VSWR data sheet.
DSA FM/AM Demodulation tips Here are some helpful tips for using the demodulation function on the Rigol DSA's.
DSA Firmware Upgrade instructions See attached for instructions to upgrade your DSA.
How to find installed DSA options Here are instructions for checking the installed options for the Rigol DSA series of spectrum analyzers.
UltraSpectrum License Activation instructions UltraSpectrum is a software package that gives remote controlled data collection and analysis for Rigol DSA spectrum analyzers. See attached for instructions on activating the software.
Bits vs. dBs Here are instructions on converting bits of resolution to dBs.
My Instrument IVI Driver does not appear in the LabVIEW tools palette. You may need to manually find and convert the IVI driver. See attachment for more details.
The instrument not recognized over the USB bus In some cases, an instrument may not be recognized over the USB bus. Here are some troubleshooting hints to help.
Are your products UL or CSA listed?
Rigol Scopes VISA Driver Installation / Rigol's UltraScope software not detect Rigol scope attached to PC via USB OR User receives "Run Time Error '48': File not found VISA32.DLL" error message when UltraScope is launched. The user either has not installed the latest available National Instruments VISA Runtime engine or the version of National Instrument’s VISA Runtime Engine included on the CD that the user installed is outdated. In both cases, the recommended solution is to visit National
Common HAM and Broadcast uses for a spectrum analyzer. A Spectrum Analyzer can be a valuable tool for any amateur radio (HAM) or broadcast Engineer. See a few of the most popular uses in this document.
How can sweep time effect my Spectrum Measurements? Sweep time and detector types can drastically effect your spectrum measurements, especially with modulated signals. See the attached note for more details.
Does the instrument clock accuracy match the external clock accuracy?
VB.NET basic instrument communication example Here is a short example on using National Instrument VISA and VB.NET to communicate with an instrument.
Useful Getting Started EMC links
What is the fastest sweep time in Zero Span mode with a Spectrum Analyzer? That is instrument dependent, but we show how to perform a quick test using a function generator in Burst mode.
Douglas Smith's EMC links Here are some helpful links to online articles presented by Douglas Smith.
NRSC AM Measurements using a DSA Here are instructions on setting up a Rigol DSA to make NRSC measurements.
How can I optimize the Peak scan measurements on a DSA spectrum analyzer? Try lowering the RBW setting. This will increase the resolution of each scan and provide a more defined peak that will be easier to identify. See attached.
How do I measure FM Deviation with a DSA? Here are instructions on using the Max Hold function to measure FM Deviation with a Rigol DSA spectrum analyzer.
How do I save a trace as a CSV file with the DSA800 series? The DSA800 series can save CSV files to an external USB memory stick. This application note shows you how.
PyVISA example of instrument control via Python and NI-VISA A short example showing instrument communications using the PyVISA 1.4 VISA wrapper with Python 2.7.9 and National Instruments VISA layer.
My spectrum analyzer displays 1st LO Unlock. What could be wrong?
1st LO unlock indicates a hardware problem. The instrument will need to be repaired.
LAN Troubleshooting using PuTTY PuTTY is an open source network terminal emulator. It can be easily configured to help troubleshoot LAN connection issues to instrumentation.
Can I use the tracking generator on a DSA as a fixed RF source? Yes. You can, using zero span. See the attached note for instructions.
NationalInstruments.Common and NationalInstruments.VisaNS are not being found with .NET
Go to Solution Explorer, right click on the file of interest (NationalInstruments.Common or NationalInstruments.VisaNS) and change Specific Version to False.
Remote activation of options on a DSA spectrum analyzer
Firmware update troubleshooting Tips Here are some tips if you are having issues updating the firmware on a Rigol product.
How do I find the version of UltraSpectrum software? Open UltraSigma, right-click on a connected DSA and select UltraSigma. Then, set the window type to advanced (upper-right-hand drop down). Next, select the ABOUT tab at the bottom of the window. See the attached note for more details.
Additional high voltage and transient protection for your spectrum analyzer Here is a circuit that may be helpful in protecting your spectrum analyzer from high voltages and transients.
Why do markers not always go to the exact frequency I set? Marker resolution is determined by the span setting. See the attached note for more information.
Application Note
How do I measure VSWR using a Spectrum Analyzer? Here are instructions on using a Spectrum Analyzer to measure VSWR for an antenna. It can be applied to other passive RF devices and cables as well.
Mixing RF Signals This note uses the TX1000 RF Demo Kit, A DG4000 function Generator, and the DSA815 Spectrum Analyzer to describe and demonstrate the fundamental operation of a multiplexer.
Hardware for a simple Mixer This note describes using a Simple Transconductance Amplifier as a Mixer.
DSA1000 Application Note
EMC Precompliance: Near Field Probes Near field probing tips for EMI precompliance testing.
Using probes with a Spectrum Analyzer This application note introduces the concept of using a passive high frequency oscilloscope probe with a spectrum analyzer.
EMC Precompliance Testing This application note covers hints and tips for implementation of precompliance steps to help lower the cost of full compliance EMC testing. It also features a series of documents that have practical use details for EMC testing.
FM signal transmission and demodulation demo This application uses a DG4162 arbitrary waveform generator and audio source to create a custom FM transmission and then a DSA-1030A spectrum analyzer to receive and demodulate the signal.
EMC Precompliance: Conducted Emission Testing This application note covers standard practices for performing EMC conducted emissions tests using a Rigol DSA-815 spectrum analyzer.
Measuring Cable Loss with a Spectrum Analyzer This Application Note covers how to measure cable loss using a spectrum analyzer outfitted with a tracking generator.
Why can't I get a DSA battery and is there a workaround for portable use? We are unable to import the Li-Ion batteries at this time. We recommend using a true sine wave inverter for portable use. See attached for performance data for a DSA800 while running on battery.